DEVELOPMENT AND EVALUATION OF MATRIX   TYPE TRANSDERMAL PATCHES OF PIOGLITAZONE HYDROCHLORIDE

Dingwoke John Emeka Francis

Department of Biochemistry, Ahmadu Bello University, Main Campus, P.M.B. 1054, Zaria, Kaduna State, Nigeria.

Corresponding author:  Email: dinhimself@yahoo.com

DOI: http://doi.org/10.22270/ujpr.v1i1.R5

ABSTRACT

 In present study, different transdermal patches of Pioglitazone hydrochloride were prepared using different polymers and evaluated on many parameters. Locally fabricated Franz diffusion cell was used for the in-vitro release study. Result revealed that there is a direct relationship with weight of the patch and drug content. The thickness lies in the range of 0.027 to 0.038mm. Average thickness was almost uniform within same formulation, a small variation in thickness was observed with different formulations.  The weight of patches lies in the range of 43.31 to 46.3 mg. The percentage of the drug content lies in the range of 96.87 to 99.28. Content uniformity studies proved that the amount of Pioglitazone hydrochloride in each patch of 2.009 cm2 was found to be fairly uniform. Percent moisture absorption was found to be in the range of 4.388 to 5.465, largest in formulations of batch code T3 and least in the batch code T2.The prepared transdermal drug delivery system of Pioglitazone hydrochloride using different polymers such as HPMC, EC, Chitosan and PVP had shown good promising results for all the evaluated parameters. However, for the in-vitro drug release and drug content result, formulation T4 was shown to be the optimized formulation, as higher percentage of drug release was obtained.

Keywords: in-vitro release, Pioglitazone hydrochloride, stability studies, transdermal patches.

INTRODUCTION

Transdermal therapeutic systems are defined as ‘self contained’ discrete dosage forms which, when applied to the intact skin, deliver the drug(s), through the skin, at a controlled rate to the systemic circulation1.Transdermal route is more convenient as compared to parenteral and oral routes, as it improve patient compliance (no pain) and avoid first pass metabolism respectively. A transdermal patch is a medicated adhesive patch that is placed above the skin to deliver a specific dose of drug through the skin with a predetermined rate of release to reach in to the systemic circulation2. Transdermal delivery provides controlled, constant administration of the drug; it allows continuous input of drugs with short biological half-lives and decreases the undesirable side effects, improve physiological and pharmacological response, avoid  the  fluctuation  in  drug  levels,  inter  and  intra patient  variations3.

Pioglitazone hydrochloride is a thiazolidinedione antidiabetic agent; it decreases insulin resistance in the periphery and in the liver resulting in increased insulin dependent glucose disposal and decreased hepatic glucose output4. It improve glucose and, in

part, lipid metabolism by increasing insulin sensitivity in insulin-sensitive tissues in diabetic patients. It is a potent and highly selective agonist for peroxisome proliferator activated receptor gamma (PPARγ) that are  present in tissues such as adipose tissue, skeletal muscle,  and liver. Activation of PPARγ nuclear receptors modulates the transcription of a  number of insulin responsive genes involved in the control of glucose and lipid  metabolism5.Pioglitazone hydrochloride was selected as a candidate for the development of transdermal patches as it has a short half-life, is extensively metabolized by  hydroxylation and oxidation and requires one to two times daily dosing. Also unfluctuating plasma  concentrations for effective management of blood sugar for long periods in  diabetic patients can be maintained by transdermal patches6.

MATERIALS AND METHODS

 Pioglitazone hydrochloride and HPMC K100 was received as gift sample from Afrik Pharmaceuticals Limited, Ethyl cellulose, and Chitosan from Dana Drugs Limited, Nigeria. 

Fabrication of the drug free films

A fixed volume of polymer solution with plasticizer was poured onto a glass petri dish. The Petri dish was placed on an even and smooth surface to ensure uniform spreading of the polymer solution. After it, solution was then placed in an oven. An inverted funnel was placed on the petri dish to facilitate the evaporation of the solvent at the controlled rate over the drying periods of 12 hrs at 40 °C. The film thus formed was retrieved by cutting along the edges with a sharp razor blade7.

Fabrication of the Pioglitazone hydrochloride loaded polymeric films

The drug loaded polymeric films were prepared in

a similar manner as mentioned above except that a weighed quantity of the 200mg Pioglitazone hydrochloride was added to the polymer solution containing the plasticizer. This solution was poured into a glass petri dish. An inverted funnel was placed on it to control the rate of evaporation. The whole assembly was maintained at 40°C in hot air oven8. After 12hrs the film was lifted from the surface of petridish after the cutting the edges with a sharp razor. The film thus formed was neutralized with 2%  NaOH and dried.

EVALUATION OF  TRANSDERMAL PATCHES

  1. Thickness

The thickness of each film was measured at five different places by means of a screw gauge9.

  1. Weight Uniformity

Five patches (area=2.009 cm2) of each film were weighed accurately and the average weight of the patch was found out10.

  1. Content Uniformity

To determine the amount of Pioglitazone hydrochloride in the patches, the patch of 2.009 cm2 area was dissolved in 10ml of phosphate buffer solution (pH 7.4) and then after dilution the amount was measured spectrophotometrically at 269 nm11.

  1. Folding Endurance

The folding endurance of the patch was determined by repeatedly folding one patch at the same place up to 290 times, which was considered satisfactory to reveal good patch properties12. The number of times the patch could be folded at the same place

without breaking gave the value of folding endurance.

  1. Percentage moisture loss

The films were weighted accurately and kept in a desiccators containing anhydrous calcium chloride. After 3 days, the films were taken out and weighed13.

  1. Percentage moisture content

The prepared films were weighed individually and kept in a dessicator containing silica at room temperature and the films were weighed again and again until they showed a constant weight. The percentage moisture content was calculated using the following formula14.

  1. Percentage moisture absorption

The films were weighed accurately and placed in the desiccator containing 100 ml of saturated solution of aluminum chloride which maintains 79.50% RH. After 3 days the films were taken out and weighed. The percentage moisture absorption was calculated using the formula15.

  1. Water vapour transmission rate

For this study vials of equal diameter were used as transmission cells. These cells were washed thoroughly an dried in an oven. About 1.0 g of fused calcium chloride was taken in the cells and the polymeric films measuring 2.009cm2 area were fixed over the brim with the help of an Adhesive16. The cells were weighed accurately and initial weight is recorded and then kept in a closed desiccator containing saturated solution of potassium chloride (200ml), containing humidity between 80-90% RH. The cells were taken out and weighed after 1, 2, 3, 4, 5, 6, and 7th day of storage. From increase in the weights the amount of water vapour transmitted and rate at which water vapour transmitted were calculated as shown below.

  1. Flatness

Longitudinal  strips of 1.6 cm in  length were cut out from the prepared medicated film and than variation in the lengths due to the non-uniformity in flatness was measured17.

Flatness was calculated by measuring constriction of strips and a zero percent constriction was considered to be equal to a hundred percent flatness.


Where, l1 = final length of each strip, and   l2 = initial length

  1. In-vitro release studies

A modified Franz-diffusion cell which is also called Keshary–Chein cell was fabricated to study the in-vitro release profile. Donor compartment of it was exposed to ambient temperature and a receptor compartment, which was maintained at 370C. The patches were stuck to an aluminum foil which was previously cut to have a diameter of 2 cm and a slightly larger patch was fixed using an water-impermeable adhesive18.

The mouth of the cell was coated with a thin layer of silicone grease to prevent leakage of the receptor fluid 1ml of the receptor fluid was withdrawn at periodic interval for 10 hrs. It was immediately replaced with 1 ml of fresh drug free buffer (pH 7.4) solution to maintain constant volume. The fluid removed, after suitable dilution with phosphate buffer was analyzed spectrophotometrically at 269 nm.

RESULTS AND DISCUSSION

 Four transdermal patches formulations of Pioglitazone hydrochloride were prepared by using different polymers i.e. HPMC, chitosan, PVP K30, EC, in different ratio. 

Thickness lies in the range of 0.027 to 0.038 mm. Average thickness was almost uniform within same formulation a small variation in thickness was observed with different formulations. The variations in thickness may be due to viscosity of polymer solutions of different formulations. The other reasons may be due to lack of temperature control which have affected the controlled evaporation of solvent from the wet film surface. There is a direct relationship with weight of the patch and drug content. The weight of patches lies in the range of 43.31 to 46.3 mg. The percentage drug content lies in the range of 96.87 to 99.28. Content uniformity studies proved that the amount of Pioglitazone hydrochloride in each patch of 2.009 cm2 was found to be fairly uniform. Percent moisture absorption was found to be in the range of 4.388 to 5.465, largest in formulations of batch code T3 and least in the batch code T2. 

Percent moisture content was found to be in the range of 2.56 to 3.21.

The folding endurance was measured manually; films were folded 290 times and if the films show any cracks it was taken as the end point. The folding endurance represents the elasticity of the patches.

The in-vitro permeation of Pioglitazone hydrochloride transdermal patches formulation was studied using locally fabricated Franz diffusion cell. The cumulative percent drug release after 12 hrs in between 51.4 to 82.11. Largest in batch code T4 and least in formulations of batch code T3. Rapid drug leakage was observed during the initial phase. However, after that a slow release occurred. It was also observed that the drug release generally decreased as the polymer ratio increased. The release of the drug was retarded due to the hydrophobic and insoluble nature of the polymers used. These results indicate hydrophilic nature of polymer PVP K30. Hydrophobic polymer has less affinity for water, this results in decrease in thermodynamic activity of the drug in the film and decreased drug release. The drug release was found to increase on increasing the concentration of hydrophilic polymer in the polymer matrix. This is due to the facts that dissolution of the aqueous soluble fraction of the polymer matrix leads to the formation of gelaneous   pores. The formation of such pores leads to a decrease in the mean diffusional path length of the drug molecules to release into the diffusion medium and hence to higher release rates.

CONCLUSION

The prepared transdermal drug delivery system of Pioglitazone hydrochloride using different polymers such as HPMC, EC, Chitosan and PVP

had shown good promising result for all the evaluated parameters. Based on the in-vitro drug release and drug content, formulation T4 was concluded as an optimized formulation, which shows its higher percentage of drug release.

CONFLICT OF INTEREST

No conflict of interest was associated with this work.

REFERENCES

  1. Satturwar PM, Fulzele SV, Dorle AK, Evaluation of polymerized rosin for the formulation and development of transdermal drug delivery system: A Technical Note. AAPS Pharm Sci Tech. 2005; 6(4): E649-54.
  2. Arora P, Mukherjee B. Design, development, physicochemical, and in vitro and in vitro evaluation of transdermal patches containing diclofenac diethyl ammonium salt. J pharm sci. 2002; 91(9), 80-84.
  3. Siewert M, Dressman J, Brown CK, Shah VP. FIP/AAPS guidelines to dissolution/in vitro release testing of novel / special dosage forms, AAPS Pharm Sci Tech. 2003; 4, 7.
  4. Aronoff S, Rosenblatt S, Braithwaite S, Egan JW, Mathisen AL, Schneider RL, et al., Pioglitazone hydrochloride monotherapy improves glycemic control in the treatment of patients with type 2 diabetes: a 6-month randomized placebocontrolled dose-response study, Diabetes Care. 2000; 1605–1611.
  5. Kipnes MS, Krosnick A, Rendell MS, JW Eagan, AL Mathisen, RL. Schneider, Pioglitazone hydrochloride in combination with sulfonylurea therapy improves glycemic control in patients withtype  2 diabetes mellitus: a randomized,  placebo controlled study, Am J Med. 2001; 10–17.
  1. Fonseca VA, Valiquett TR, Huang SM, MN Ghazzi, Whitecomb RW, Troglitazone monotherapy improves glycemic control in patients with type 2 diabetes mellitus: a randomized, controlled study. The Troglitazone Study Group. J Clin Endocrinol Metab. 1998; 3169–3176.
  2. Rao YM, Gannu R, Vishnu YV and Kishan V, Development of nitrendipine transdermal patches for in vitro and ex vitro characterization. Curr Drug Deliv. 2007; 4: 69-76.
  3. Devi KV, Saisivam S, Maria GR, Deepti PU, Design and evaluation of matrix diffusion controlled transdermal patches of verapamil hydrochloride. Drug Dev Ind Pharm. 2003; 29(5): 495-503.
  4. Sanjoy M, Thimmasetty J, Ratan GN, Kilarimath BH, Formulation and evaluation of Crvedilol transdermal patches. Int Res J Pharm. 2011; 2 (1), 237-248.
  5. Shingade G, Quazi A, Sabale P. Grampurohit N, Gadhave M, Jadhav S, Gaikwad D, Review on: recent trend on transdermal drug delivery system. J Drug Delivery Therapeutics. 2012; 2(1): 66-75.
  6. Gondaliya D, Pundarikakshudu K. Studies in Formulation and Pharmacotechnical Evaluation of Controlled Release Transdermal Delivery System of Bupropion. AAPS Pharm SciTech. 2003; 4(1) 3, 124-132.
  7. 12. Arora P, Mukherjee B, Design, development, physicochemical and in vitro, in vitro evaluation of transdermal patches containing diclofenac diethyl ammonium salt. J Pharma Sci. 2002; 91(9), 2076-2089.
  1. Chandrashekhra N S. Current Status and Future Prospects in Transdermal Drug Delivery. Pharmainfo.net. 2008; 5, 13-18.
  2. Panchaxari D, Pampana S, Pal T, Devabhaktuni B, Aravapalli A. Design and characterization of diclofenac diethylamine transdermal patch using silicone and acrylic adhesives combination. DARU J Pharm Sci. 2013; 21:6
  3. Li J, Masso L, Rendon S. Quantitative evaluation of adhesive properties and drug-adhesive interactions for transdermal drug delivery formulations using linear solvation energy relationships. J Control Release. 2002; 18; 82(1), 1-16.
  4. Sharma N, Agrawal G, Rana A, Alibhat Z and Kumar D. A Review: Transdermal drug delivery system: a tool for novel drug delivery system. Int J Drug Devt Res. 2011; 3(3): 70-84.
  5. Kurz A, Farlow M and Lefevre G. Pharmacokinetics of a novel transdermal rivastigmine patch for the treatment of Alzheimer’s disease: a review. Int J Clin Practice. 2009; 63(5): 799–805.
  6. Sankar V, Sivanand V. Design and evaluation of nifedipine transdermal patches. Indian J Pharm Sci. 2003; 65 (5), 510 – 515.

Table 1: Compositions of the Pioglitazone hydrochloride transdermal patches

Batch

Polymer ratio

Solvent

Plasticizer (20%)

T1

Chitosan :Ethyl cellulose:: 20:80 

Acetic acid (1 % w/v)

Castor oil

T2

Chitosan :Ethyl cellulose:: 80:20 

Acetic acid (1 % w/v)

Castor oil

T3

HPMC:PVP K30::20:80

Dichloromethane (2% w/v)

Glycerine

T4

HPMC:PVP K30::20:80

Dichloromethane (2% w/v)

Glycerine

 

Table 2:  Physical Characterization of transdermal patches

Parameter

T1

T2

T3

T4

Physical Appearance

Smooth flexible but wrinkled

Smooth tough

Hard and tough

Smooth tough

 

Thickness (mm) ± SD

0.028±0.32

0.031±0.25

0.027±0.58

0.038±0.02

Mass uniformity (mg)

46.3±0.35

45.7±0.51

44.3±0.16

43.31±0.23

% Drug content

99.28±0.34

98.66±0.34

97.42±0.12

96.87± 0.42

% Moisture Content

3.21±0.25

2.56 ±0.26

2.78 ±0.25

2.88±0.25

% Moisture absorption

5.342±0.46

4.388±0.82

5.465 ±0.58

4.521±0.33

% Moisture loss  

3.763±0.14

3.573±0.15

3.146 ±0.24

3.485±0.32

WVTR (g/cm2/hrs

1.521X10-4± 0.12

1.489 X10-4± 0.27

1.543X10-4±0.08

1.443X10-4± 0.12

Folding endurance

> 278

> 285

> 262

> 270

Flatness

100%

100%

100%

100%

 

 

Figure 1: % drug released from Pioglitazone hydrochloride transdermal patches