PRIMARY STABILITY FOR SHORT DENTAL IMPLANT WITH DEEP THREADED IN POSTERIOR MAXILLA DURING EARLY HEALING PERIOD

  • Mohammed Ahmed Qasem Ahmed Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Sana'a University, Republic of Yemen.
  • Yaser Ahmed Salem Alrubaidi Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Sana'a University, Republic of Yemen.
  • Yahya Abdullah Ahmed Alhadi Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Sana'a University, Republic of Yemen.
  • Tagreed Ahmed Al-Kabsi Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Sana'a University, Republic of Yemen.
  • Hassan Abdulwahab Al-Shamahy Department of Basic Sciences, Faculty of Dentistry, Sana’a University, Republic of Yemen. Medical Microbiology and Clinical Immunology Department, Faculty of Medicine and Health Sciences, Sana’a University.
10.22270/ujpr.v10i5.1423

Keywords:

Implant stability quotient, insertion torque, posterior maxilla, primary stability, resonance frequency analysis, short dental implants

Abstract

Background and aim: Because they provide a dependable way to replace lost teeth and restore both function and appearance, dental implants have completely transformed the profession of restorative dentistry. These artificial tooth roots, which are usually composed of titanium, are placed into the mandible to support crowns, bridges, or dentures. The study's objective was to assess the main stability of a short, deep-threaded dental implant in the posterior maxilla during the early healing phase. It focused on the correlation between the values of the implant stability quotient (ISQ) and insertion torque (IT).

Methodology: A prospective clinical study was conducted on 20 patients requiring posterior maxillary implants. Short implants (Ø4 × 7 mm) were placed using the Megagen Any Ridge system. Primary stability was assessed by measuring IT at insertion and ISQ via resonance frequency analysis (RFA) at baseline and weekly for four weeks. Variables such as bone density, age, gender, and implant site distribution were also recorded.

Results: Implants with moderate IT (26–35 Ncm) maintained stable ISQ values (50–65), suggesting optimal primary stability. Low IT (15–25 Ncm) implants showed gradual improvement in ISQ (from 45 to 64), whereas resulted high IT (36–45 Ncm in gradually decrease in ISQ (from 65-52). Bone density was predominantly D3 (50%) and D4 (40 %). No significant correlation was found between IT and ISQ over time (Spearman’s rho: 0.20–0.55, p> 0.05).

Conclusion: Short, deep-threaded implants placed with moderate insertion torque provide optimal primary stability in the posterior maxilla. Excessive torque increases the risk of loose the stability. Regular ISQ monitoring is recommended during the healing phase to guide clinical decision-making.

                 

Peer Review History:

Received 4 August 2025;   Reviewed 11 September 2025; Accepted 18 October; Available online 15 November 2025

Academic Editor: Prof. Dr. Gorkem Dulgerorcid22.jpg, Duzce University, Turkey, gorkemdulger@yandex.com

Reviewers:

orcid22.jpgDr. Kingsley C Anukam, University of Benin, Nigeria, kanukam@gmail.com

orcid22.jpgDr. Liliya Logoyda, Horbachevsky Ternopil State Medical University, Ukraine, logojda@tdmu.edu.ua

Downloads

Download data is not yet available.
Crossmark
Statistics
53 Views | 24 Downloads
Dimension Citations

Published

2025-11-15

How to Cite

Mohammed Ahmed Qasem Ahmed, Yaser Ahmed Salem Alrubaidi, Yahya Abdullah Ahmed Alhadi, Tagreed Ahmed Al-Kabsi, and Hassan Abdulwahab Al-Shamahy. “PRIMARY STABILITY FOR SHORT DENTAL IMPLANT WITH DEEP THREADED IN POSTERIOR MAXILLA DURING EARLY HEALING PERIOD”. Universal Journal of Pharmaceutical Research, vol. 10, no. 5, Nov. 2025, doi:10.22270/ujpr.v10i5.1423.

Issue

Section

Research Articles

Most read articles by the same author(s)

1 2 3 > >>